Hot-dip galvanized rigid steel conduit for underground and hazardous locations; heavy-wall ANSI 80, threads on both ends, 1/2″–6″ sizes, 3 m lengths. UL listed, SASO, BS and ANSI certified.
LFMC with electro-galvanized steel core and PVC or LSZH (LZOH) jacket. UL 360 (E549138), NEC Art. 350, IP67, -30°C to +90°C, sizes 3/8″–4″, rolls 15–25 m.

Electrical Metallic Tubing in galvanized steel, 1/2″–4″; thin-wall design for commercial branch circuits; AWG chart per NEC Annex C; cut and threaded on site.

Zinc die-cast compression connectors and couplings for EMT, UL 514B listed; rain-tight and concrete-tight types; sizes 1/2″–2″ for commercial and industrial conduit runs.

Multi-run EMT conduit banks with spacers and pull boxes for service entrance and distribution feeders; concrete-encased installation per NEC Article 300.

Heavy-wall galvanized rigid steel conduit for underground and hazardous locations; threads on both ends; UL 6 listed; maximum protection for service and feeder circuits.
Barqan conduit systems cover the mechanical protection side of an installation: electrical metallic tubing, rigid metal conduit, liquid-tight flexible conduit and the connectors, couplings and pull elbows that finish the run. Alzab Algharbiyah supplies the range from Dammam to projects across Saudi Arabia, and the categories below follow the structure of the Barqan brand page, which sits inside our wider products directory. Fittings are UL 514B listed, and conduit carries UL, SASO, BS and ANSI certification.
Rigid steel conduit is hot-dip galvanized with a heavy ANSI 80 wall, threaded on both ends, from 1/2 to 6 in in 3 m lengths and certified to UL, SASO, BS and ANSI standards for underground and hazardous locations. The rigid metal conduit option is UL 6 listed and gives maximum protection for service and feeder circuits. Electrical metallic tubing covers 1/2 to 4 in in galvanized steel with a thin-wall design for commercial branch circuits, sized against NEC Annex C and cut and threaded on site.
Liquid-tight flexible conduit uses an electro-galvanized steel core under a PVC or LSZH jacket, listed to UL 360 (E549138) and built to NEC Article 350 with IP67 sealing from -30 to +90 degrees, in 3/8 to 4 in on 15 to 25 m rolls. Multi-run EMT conduit banks with spacers and pull boxes handle concrete-encased service entrance work to NEC Article 300.
The fittings group starts with the liquid-tight 90 degree angle connector, a zinc die-cast entry for boxes and enclosures in 3/8 to 4 in (UL 514B, E506413), and the liquid-tight stainless steel straight connector for petrochemical, refinery and marine environments where IP67 and corrosion resistance matter. The EMT pull elbow is a zinc die-cast 90 degree unit with a removable cover that makes wire pulling straightforward, listed to UL 514B (E506415) in 1/2 to 2 in.
EMT connectors and couplings complete the system: set-screw types, compression types, rain-tight compression variants and pull elbows across commercial and industrial conduit runs, all to UL 514B (E506415). Separate zinc die-cast EMT compression connectors and couplings cover 1/2 to 2 in in rain-tight and concrete-tight versions for exposed and buried runs.
Conduit rarely ships alone. Alzab can pair these runs with the Barqan cable trays category for tray and ladder routes, and with OBO Bettermann VBS connection and fastening systems where terminals, glands and fastenings are specified on the same schedule. Request a quote through our contact page for your project schedule.